Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
This PR contains the following updates:
v0.12.0→v0.13.0Release Notes
go-opentype/opentype (github.com/go-opentype/opentype)
v0.13.0: — a ceiling that a 32-bit int walked throughCompare Source
Judge a table's extent in int64
The table-directory reader refused an out-of-range table by adding two uint32s
converted with
int():intis 32 bits on a 32-bit build, so a length of0xFFFFFFFFbecomes −1.off+lengththen comes out smaller thanoff, the check passes a table thatis not in the file, and the slice that follows panics —
b[184:183]— in areader whose whole purpose is to refuse a malformed font rather than crash on one.
TestParseErrors/table_out_of_rangealready covered this and was alreadycorrect. It had simply never been run on a machine where an
intis 32 bits.New: the tests run on six architectures
riscv64,loong64,ppc64le,s390x(big-endian),386andarm(32-bitint) — underqemu-user-static, except386, which runs natively becauseqemu-i386loses the guest's floating-point state across the signal Go deliversfor asynchronous preemption (5 failures in 8 identical lanes emulated, 0 in 8
native).
The CI previously cross-compiled for the 64-bit four and ran on none of them.
Every big-endian lane was green from the first run — a font file is a big-endian
container, so the readers had nothing to unlearn. Both 32-bit lanes failed, and
the fix above is what they found.